Transmitters
 

PR ELECTRONICS

PRetop 5331A

  • RTD, TC, Ohm, or mV input
  • Extremely high measurement accuracy
  • Version with galvanic isolation
  • Programmable sensor error value
  • For DIN form B sensor head mounting

For more detailed information: (5331A.pdf: 174k)

PRetop 5333A

  • RTD or Ohm input
  • High measurement accuracy
  • 3-wire connection
  • Programmable sensor error value
  • For DIN form B sensor head mounting

For more detailed information: (5333A.pdf: 130k)

PRetop 5334A

  • TC input
  • High measurement accuracy
  • Galvanic isolation
  • Programmable sensor error value
  • For DIN form B sensor head mounting

For more detailed information: (5334A.pdf: 126k)



PR Electronics Full Range Product Guide
(PR-Product-Guide.pdf: 1.9mb)


INTECH

• DC Signals • Bridge • Resistance • Potentiometer • RTD • Thermocouple • AC Current • Humidity

PI-Series

  • Input and output ranges are field programmable
  • Bi-polar – Input and output signals
  • 1.6 kV isolation
  • 0.1% accuracy
  • Universal power supply, 3 optional ranges
    High 70 ~ 270V AC and 80 ~ 380V DC
    – Medium 24 ~ 80V AC and 20 ~ 90V DC
    – Low 8 ~ 20V AC and 8 ~ 30V DC
  • Plug-in – DIN rail mount base
  • Special calibration available

For more detailed information: (PI-Short-Form.pdf: 814k)

 

LPI-Series

  • Output, 4 ~ 20 mA loop powered
  • 2 kV isolation
  • 0.1% accuracy
  • 40 ~ 200mV output test signal
  • LED indication of loop current
  • Special calibration available

For more detailed information: (LPI-Short-Form.pdf: 517k)

 

LPN-Series

  • Output, 4 ~ 20 mA loop powered
  • 2 kV isolation
  • 0.1% accuracy
  • 40 ~ 200mV output test signal
  • LED indication of loop current
  • Special calibration available
  • Non-isolating

For more detailed information: (LPN-Short-Form.pdf: 280k)

 

Micro 2100-Series

Each input is user selectable in Micro Scan version 4 software to any of the following:

  • Thermocouple, RTD (Pt100/Pt 1000), mA, mV, volts
  • 16 analogue differential inputs (RTD single ended)
  • 4 digital inputs, for counting or on/off status
  • 2 relay outputs, for control or alarm functions
  • 2 analogue outputs
  • Comms – RS485 or RS422 selectable, RS 232 optional
  • Input expansion, up to four 16 input 2100-M units
  • Output expansion, one 16 relay 2100-R unit
  • Radio modem compatible
  • Memory expansion for ‘stand alone’ logging etc.
  • 16 resident ‘computer free’ on-board controllers. Use with the two on-board relays or the 2100-R unit.

For more detailed information: (2100-Family.pdf: 153k)

 